Du er her:»»»»Vibranivo VN 6020 gaffelmelder – Rustfrit stål 1.4301 (304)

Vibranivo VN 6020 gaffelmelder – Rustfrit stål 1.4301 (304)

Velegnet til materialer med en densitet på under 5 g/l.
Robust kompakt udførelse, til meget krævende opgaver.

Velegnet til

  • Korn / foderstoffer
  • Træpiller
  • Ekstremt lette materialer
  • Plastgranulat og pulver
  • Alle former for pulver
  • … og meget andet
Pos.4 Electronic moduleAvailable for certificates (pos.2)
0W/A/EY/B/VR/C/KT/D/LMNPSU
E
L
D
K
M
N
N
Varenummer (SKU): N/A Varekategori: Tag:

Beskrivelse

  • Forstærket, solid udførsel i rustfri stål
  • Ingen vedligeholdelse
  • Nem installation i top

Følsomhed
Fra 5g/l

Længde
235mm

Proces Temperatur
-40ºC to +150ºC

Proces Tryk
-1bar to +16bar

Elektronik
Relay SPDT / DPDT 19-230V AC og19-55V DC; PNP 18-50V DC; 2-wire contactless 19-230V AC/DC; NAMUR IEC 60947-5-6 (2-wire); 8/16mA or 4-20mA (2-wire)

Godkendelser
ATEX, IEC-Ex, FM, CSA, EHEDG

Kontakt os for leveringstider

Yderligere information

Certificate

(A) IEC-Ex/ INMETRO Zone 20 and 20/21 – Dust Ignition Proof (VN1020), (B) IEC-Ex/ INMETRO Zone 20 and 20/21 Zone 0 and 0/1 Intrinsic Safe/ Dust Ignition Proof (VN1020), (C) IEC-Ex/ INMETRO Zone 20/21 Zone 1 Flameproof/ Increased Safety/ Dust Ignition Proof (VN5020), (D) IEC-Ex/ INMETRO Zone 20/21 Zone 1 Flameproof/ Dust Ignition Proof (VN5020), (K) TR-CU Zone 20/21 Zone 1 Flameproof/ Increased Safety/ Dust Ignition Proof (VN5020), (L) TR-CU Zone 20/21 Zone 1 Flameproof/ Dust Ignition Proof (VN5020), (N) FM/ CSA Cl. II, III, Div.1 – Dust Ignition Proof (VN5020), (P) FM/ CSA Cl. II, III, Div.1 Cl. I Div.1/ Zone 0 Intrinsic Safe/ Dust Ignition Proof (VN6020), (R) ATEX Zone 20/21 Zone 1 Flameproof/ Increased Safety/ Dust Ignition Proof (VN5020), (S) FM/ CSA Cl. II, III, Div.1 Zone 1 Flameproof/ Increased Safety/ Dust Ignition Proof (VN5020), (T) ATEX Zone 20/21 Zone 1 Flameproof/ Dust Ignition Proof (VN5020), (U) FM/ CSA Cl. II, III, Div.1 Cl. I Div.1/ Zone 1 Explosion Proof/ Dust Ignition Proof (VN5020), (W) ATEX Zone 20 and 20/21 – Dust Ignition Proof (VN1020), (Y) ATEX Zone 20 and 20/21 Zone 0 and 0/1 Intrinsic Safe/ Dust Ignition Proof (VN1020), (0) CE/TR-CU, (M) FM General Purpose

Temperature extended shaft

(1) without (up to Tprocess = 150°C (302°F) at Tamb < 40°C (104°F)), (2) with (up to Tprocess = 150°C (302°F) at Tamb > 40°C (104°F))

Electronic module

(L) Relay DPDT 19 .. 230 V AC 19 .. 36 V DC (VN2020), (L) Relay DPDT 19 .. 230 V AC 19 .. 55 V DC (VN2020), (N) 8/16 mA or 4-20 mA 12.5 .. 36 V* DC 2-wire, (D) PNP – 18 .. 50 V DC, (E) Relay SPDT – 19 .. 230 V AC – 19 .. 55 V DC, (K) 2-wire without contact – 19 .. 230 V AC/ DC, (M) NAMUR IEC 60947-5-6 2-wire, (N) 8/16 mA – 12.5 .. 36 V DC 2-wire

Process connection 5

(A) Thread R 1½", conical EN 10226, (B) Thread NPT 1½", conical ANSI B1.20.1, (G) Cap nut (only with EHEDG (pos.30), not with pos.2 C,D,R,S,T,U), (L) Flange DN100 PN6, EN 1092-1 (max. 6 bar (87 psi))(VN1020), (M) Flange DN100 PN16, EN 1092-1 (VN1020), (P) Triclamp 2" (DN50) ISO 2852 (VN1020), (S) Flange 2" 150lbs ANSI B16.5 (VN1020), (T) Flange 3" 150lbs ANSI B16.5 (VN1020), (U) Flange 4" 150lbs ANSI B16.5 (VN1020)

Material of process connection/ extension "L"

(1) Stainless steel 1.4301 (304)/ Flange 1.4541 (321)

Ved at bruge hjemmesiden accepterer du brugen af cookies og vores persondatapolitik mere information